energy saving made easy







Opt-i-Mizer EOM-B

 

EOM-B is a 3 phase 4 wire advanced microprocessor controlled,
energy saving Basic controller.
Specifically designed for use with HID light units such as:
High Pressure Sodium, Metal Halide, Mercury Vapor,
and Fluorescent Lamps.

Features

  • Totally self-contained microprocessor control.
  • Built-in programmable timer, under and over voltage protection.
  • Requires no changes to customers existing lighting infrastructure.
  • Provides up to 30% reduction in Energy Cost.
  • Built-in Manual Bypass facility.
  • No Harmonic Distortion with pure Sine Wave Output.
  • More than 98.5% Efficient.
  • Built-in winding over temperature trip (thermo element switch)
  • Increases lamp life by up to 300%.
  • Modular design with minimal maintenance.
  • CE and IEC approved to 60439-1
  • Approved by OSRAM and Philips

Range 

  • EOM-B-30A 400V 3ph. 4W 30A per phase
    Un-enclosed Dimensions: 300mm W x 610mm H x 270mm D
  • EOM-B-50A 400V 3ph. 4W 50A per phase
    Un-enclosed Dimensions: 300mm W x 610mm H x 270mm D
  • EOM-B-80A 400V 3ph. 4W 80A per phase
    Un-enclosed Dimensions: 300mm W x 610mm H x 270mm D
  • EOM-B-100A 400V 3ph. 4W 100A per phase
    Un-enclosed Dimensions: 388mm W x 711mm H x 291mm D
  • EOM-B-125A 400V 3ph. 4W 125A per phase
    Un-enclosed Dimensions: 388mm W x 711mm H x 291mm D
  • EOM-B-160A 400V 3ph. 4W 160A per phase
    Un-enclosed Dimensions: 388mm W x 711mm H x 291mm D
  • EOM-B-210A 400V 3ph. 4W 220A per phase
    Un-enclosed Dimensions: 630mm W x 711mm H x 350mm D

Technical Specification

  • Input voltage: 400V (3x230VAC)
  • Output voltage: Input voltage less 25V (opt. 22V or 20V or 15V)
  • Frequency: 50-60Hz
  • Energy saving: Above 20% (depend on voltage reduction)
  • Power Range: (Capacity) 3 x 30A up to 3 x 220A
  • Control Voltage: 230VAC+15%
  • Min input voltage protection: 170-230V
  • Fault indicator Lamp: LEDs
  • Insulation: 2.5kV
  • Ambient  Temp: -20ºC to +50ºC
  • Operation mode: Under input Voltage protection.
  • By Pass Switch: manual
  • Standard CE, EN60439-1 (safety approval)

Method of Operation

All EOM-B units are designed for installation within the contactor supply cable to the distribution boards of the lighting system.

(Input contactor should be installed before the controller)

The EOM-B is usually mounted next to, as far as is practicable, the lighting distribution board.

Protection

The supply and load are protected by suitably rated Miniature Circuit Breakers.

The EOM-B is equipped with thermal trips on the windings of the coils that will trip the supply on over temperature alarm.

Under and over voltage is a preset parameter of the microprocessor and will activate an alarm and in the case of under input voltage will prevent the unit from going into ‘Energy Saving’ mode.

The EOM-B is fitted with a Manual Bypass Switch.

OPERATING PRINCIPLE

After the power is supplied to the controller and if the ‘ON’ command exists, the controller supplies full voltage to the system.

Providing the ‘Energy Saving’ contact is enabled, the programmed delay time will commence, which is fixed at 6 minutes.

After the timer expires the EOM-B is in Energy Saving’ mode and the output voltage is reduced by approximately 10% (e.g. if the input voltage is 230V, the output voltage will be 205V).

In the case of power failure, after the power returns (restart), and all the control signals (‘ON’ & ‘Energy Saving’) are still present, the controller provides full voltage to the system and energy saving will begins after the time delay as mentioned above.

If, during energy saving mode, it becomes necessary to restart some or all lamps, this can be achieved by opening the connection to terminals 3 & 4 (disable ‘Energy Saving’ mode).

The unit will now supply full voltage until the ‘Energy Saving’ mode is enabled and the timer has elapsed.

 